Auto Focus
Being Auto Focus StaRk XRF makes a simple and fast for sample positioning which helps in saving time for those requiring continuous operation.
Secure Non Editable Software
X-MasteR software is user friendly and easy to use with non-editable results. X-MasteR is the heart of all Aczet’s X-Ray instruments, enabling the collection of information regarding precious metals, coating thickness and material analysis. X-MasteR has both Empirical and Fundamental method of measurement.
X-MasteR has ease for creation of required application for coating thickness.
Stark PIN | Detector | Measuring Direction | Applied Application | X-ray Tube | High Voltage |
High Resolution SI-PIN | Bottom to Top | Gold & Silver Analysis in jewellery and alloys, Coating Thickness Measurement on Metals | Mini-focus,high performance,Long Life, High efficiency, tungsten target oil cooled W-target, Spot 0.2mm-0.8mm, | 0 - 50kV (1.2mA) Software Control Optimized | |
Get A Quote
Full Specs
|
Detector | High Resolution SI-PIN | Measuring Direction | Bottom to Top |
Applied Application | Gold & Silver Analysis in jewellery and alloys, Coating Thickness Measurement on Metals | X-ray Tube | Mini-focus,high performance,Long Life, High efficiency, tungsten target oil cooled W-target, Spot 0.2mm-0.8mm, |
High Voltage | 0 - 50kV (1.2mA) Software Control Optimized | Measurement Time | 30 to 60 seconds |
Collimator | 0.3mmØ or 0.5mmØ, Optional four positions Collimator changer | Dimension (WxDxH) | 350 x 450 x 310 mm (WxDxH) |
Weight | 32 kg |
Stark SDD | Detector | Measuring Direction | Applied Application | X-ray Tube | High Voltage |
High Resolution SI-PIN | Bottom to Top | Gold and Silver Analysis in jewellery and alloys, Coating Thickness Measurements on Metals | Mini-focus,high performance,Long Life, High efficiency, tungsten target oil cooled W-target, Spot 0.2mm-0.8mm, | 0 - 50kV (1.2mA) Software Control Optimized | |
Get A Quote
Full Specs
|
Detector | High Resolution SI-PIN | Measuring Direction | Bottom to Top |
Applied Application | Gold and Silver Analysis in jewellery and alloys, Coating Thickness Measurements on Metals | X-ray Tube | Mini-focus,high performance,Long Life, High efficiency, tungsten target oil cooled W-target, Spot 0.2mm-0.8mm, |
High Voltage | 0 - 50kV (1.2mA) Software Control Optimized | Measurement Time | 10 to 60 seconds |
Weight | 32 kg | Collimator | 0.3mmØ or 0.5mmØ, Optional four positions Collimator changer |
Dimension (WxDxH) | 350 x 450 x 310 mm (WxDxH) |
Stark SDD Pro | Detector | Applied Application | X-ray Tube | High Voltage | Collimator |
Silicon Drift Detector (SDD) | Bottom to Top | Gold and Silver Analysis in jewellery and alloys, Coating Thickness Measurements on Metals | Mini-focus,high performance,Long Life, High efficiency, tungsten target oil cooled W-target, Spot 0.2mm-0.8mm | 0 - 50kV (1.2mA) Software Control Optimized | |
Get A Quote
Full Specs
|
Detector | Silicon Drift Detector (SDD) | Applied Application | Bottom to Top |
X-ray Tube | Gold and Silver Analysis in jewellery and alloys, Coating Thickness Measurements on Metals | High Voltage | Mini-focus,high performance,Long Life, High efficiency, tungsten target oil cooled W-target, Spot 0.2mm-0.8mm |
Collimator | 0 - 50kV (1.2mA) Software Control Optimized | Dimension (WxDxH) | 0.3mmØ or 0.5mmØ, Optional four positions Collimator changer |
Measurement Time | 350 x 450 x 310 mm (WxDxH) | Weight | 10 to 60 seconds |
Stark | Measuring Direction | Applied Application | X-ray Tube | High Voltage | Detector |
Bottom to Top | Gold, Silver & Platinum Analysis in Jewellery and alloys | Powerful 50 Watts air cooling X-ray tube | 50kV (1.2mA) Software Control Optimized | High performance SDD | |
Get A Quote
Full Specs
|
Measuring Direction | Bottom to Top | Applied Application | Gold, Silver & Platinum Analysis in Jewellery and alloys |
X-ray Tube | Powerful 50 Watts air cooling X-ray tube | High Voltage | 50kV (1.2mA) Software Control Optimized |
Detector | High performance SDD | Measurement Time | 10 - 60 sec |
Collimator | 0.3mm⌀ or 0.5mm⌀, Optional four positions Collimator changer | Sample Stage | Fixed Sample Positioning |
Power | 220ACV 50/60HZ | Inside Chamber | 300 x 310 x 104 mm (W x D x H) |
Weight | 32 kg | Dimension (WxDxH) | 400 x 405 x 455mm (W x D x H) |