Analytical balances are essential tools in various scientific disciplines. Our analytical balances sound particularly impressive, with a wide range of capacities and a high level of accuracy that makes them an excellent choice for any analytical operation. It's great to know that with a readability of 0.1 mg and up to 400 g, I can trust that the measurements will be precise.

Reliable and precise results

The sensor truly stands out with its unparalleled design based on electromagnetic force compensation (EMFC). Its exceptional performance meets the highest international standards. I am truly impressed by its unique features and the results it delivers.
Internal Calibration Professional Level CY-C Series
Motorized built-in weight internal calibration ensures precise weighing performance in any condition.
Environmental influence Professional Level CY-C Series
The Perfect Self Automatic Calibration (PSAC) function maintains accuracy by automatically calibrating the system based on time or temperature changes.
Standard Level CY Series External calibration
is the process of manually calibrating a balance with a predetermined mass.                                                                   
 

Revolution in Mass Measurement Quantity

Our Analytical balance  sets a new benchmark for mass measurement quality with the best weighing accuracy and sd ≤ 1d repeatability. We adhere to strict USP requirements (chapters 41 and 1251) to ensure the highest level of quality in our measurements.
Overload Protection
Monitor the built-in capacity tracker to prevent overloading the weighing cell.
 

Strong and Sturdy Construction

• The solid construction and high-quality materials
• Solid Performance
• A protective cover is supplied as standard to safeguard

Efficient Functioning

• The balance's glass draft shield with a three-side opening chamber is exceptionally spacious and user-friendly, providing ample space to work without the worry of spills.
• Protection Class
The balance is IP 54 protection qualified which protects from dust and splashes of water.

10 Easy-to-use Built-in-Applications

• including density determination, check weighing, totaling, and formulation, simplify your routine weighing tasks.

 

Excellent Readable Display

• Bright LED backlit LCD display and large numbers
• LCD glass with higher contrast and wider viewing angle.
• Intuitive interface

 

Efficient Communication

• Standard USB and RS232 interface
• Windows direct communication to MS Excel or any other Windows applications

GLP Documentation

• Built-in real-time clock make sure that the data are a true reflection of the test results & is the traceable document in compliance with SOPS and GLP regulation.

Easy Leveling

• Easy to view Round Circular Bubble Level
•  Large adjustable feet
• Levelling your balance is quick and easy.

Effortless Cleaning

• The draft shields can be easily dismantled and assembled, making it  convenient to keep the balance clean and tidy.

Application Industries

• Pharmaceutical, Cosmeceuticals, and Biotechnology Products Testing Laboratories
• Chemical and Material Testing laboratories
• Food and Beverages Testing Laboratories
• Petroleum Product Testing Laboratories
• Research  & NABL Laboratories and Academic Institutes

Touch Screen CY-A Series Model Maximum Capacity Minimum load Readability Repeatability
CY 224 A 220 gm 1 mg 0.1 mg 0.1 mg
Get A Quote
Full Specs
Model CY 224 A Maximum Capacity 220 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability 0.1 mg Linearity ±0.2 mg
Tare Range - 220 gm Minimum Sample Weight (as per USP) 160 mg
Minimum Sample Weight (U=1% K=2) 16 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Touch Screen
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 124 C 120 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 124 C Maximum Capacity 120 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range - 120 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 224 C 220 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 224 C Maximum Capacity 220 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range - 220 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 304 C 300 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 304 C Maximum Capacity 300 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.3 mg
Tare Range - 300 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 324 C 320 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 324 C Maximum Capacity 320 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.3 mg
Tare Range - 320 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Weight approx. 342.5 x 212 x 341 / Chamber Height 228.5 Balance Size (WxDxH) mm 9.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 404 C 400 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 404 C Maximum Capacity 400 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.6 mg
Tare Range - 400 Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 64 60 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 64 Maximum Capacity 60 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range - 60 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 124 120 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 124 Maximum Capacity 120 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range - 120 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 224 220 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 224 Maximum Capacity 220 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range - 220 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 304 300 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 304 Maximum Capacity 300 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.3 mg
Tare Range - 300 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 324 320 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 324 Maximum Capacity 320 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.3 mg
Tare Range - 320 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 404 400 gm 1 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 404 Maximum Capacity 400 gm
Minimum load 1 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.6 mg
Tare Range - 400 gm Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 mm Ø
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18º to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg