THE BRILLIANT SENSOR :
The sensor truly stands out with its unparalleled design based on electromagnetic force compensation (EMFC). Its exceptional performance meets the highest international standards. I am truly impressed by its unique features and the results it delivers.
Technology:
High-Performance Jewellery Balances are based on Electromagnetic force compensation principal. The compensated principal is superior to conventional systems due to improved dynamic & static performance.
Display:
High Contrast Backlit LCD display is exceptionally easy to read under any room lighting conditions.
Below Weighing Hook:
Hook for weighing below the balance.
Capacity Bar:
A capacity Bar graph shows how much of the weighing range is still available.
Flexibility:
User can weigh various weighing units like mg, g, ct, oz, dwt, tola, mommes, baht, grain, mesghal, ozt, Hong Kong Taels, Singapore Taels, Taiwan Taels. This extends flexibility to the user.
Easy Data Transfer:
Only a single cable is required to transfer balance data to MS Excel or other Windows application through RS232C interface. No troublesome interface attachment or software installation is necessary. This unique feature makes Aczet balance extremely convenient for data analysis.
Optional USB Connection is available for easy Data Transfer.
Convenience:
These Balances are equipped with Larger Draft shield & Windshield chamber with giving more operational space.
Optional:
Aczet Data Printer is available for printing Weighing Data with Time & Date Formulation. Can connect with any Diamond & Jewellery Balances of ACZET. Date, Time Statistic & Totalization function which enables for printing any Diamond & Jewellery Weights printouts

CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 265 C 60 / 220 gm 1 mg 0.01 /0.1 mg ±0.02 / 0.1 mg
Get A Quote
Full Specs
Model CY 265 C Maximum Capacity 60 / 220 gm
Minimum load 1 mg Readability 0.01 /0.1 mg
Repeatability ±0.02 / 0.1 mg Linearity ±0.04 / 0.2 mg
Tare Range Full Capacity Minimum Sample Weight (U=1% K=2) 2 mg
Minimum Sample Weight (as per USP) 20 mg Pan Size 80Ø Grid pan
Response Time 5-8 sec Display Alpha Numeric Backlite LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15ºC to 35ºC Sensitivity Drift ± 1 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adapter, input 100 ~ 240 0.8A output 13V / 1.5A, 50 / 60Hz Compliance ISO, GLP / GMP Compliance
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height : 228.5) Net Weight / Gross Weight 8.0 kg / 9.30 kg
CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 224C 220 gm 10 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 224C Maximum Capacity 220 gm
Minimum load 10 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range Full Capacity Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 Ø mm
Response Time 2-3 sec Display Alpha Numeric Backlite LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18ºC to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 124C 120 gm 10 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 124C Maximum Capacity 120 gm
Minimum load 10 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range Full Capacity Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90Ø mm
Response Time 2-3 sec Display Alpha Numeric Backlite LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18ºC to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 Kg
CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 64 60 gm 10 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 64 Maximum Capacity 60 gm
Minimum load 10 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range Full Capacity Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90Ø mm
Response Time 2-3 sec Display Alpha Numeric Backlite LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18ºC to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 224 220 gm 10 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 224 Maximum Capacity 220 gm
Minimum load 10 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range Full Capacity Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90Ø mm
Response Time 2-3 sec Display Alpha Numeric Backlite LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18ºC to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 124 120 gm 10 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 124 Maximum Capacity 120 gm
Minimum load 10 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range Full Capacity Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90Ø mm
Response Time 2-3 sec Display Alpha Numeric Backlite LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18ºC to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg
CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 64C 60 gm 10 mg 0.1 mg ±0.1 mg
Get A Quote
Full Specs
Model CY 64C Maximum Capacity 60 gm
Minimum load 10 mg Readability 0.1 mg
Repeatability ±0.1 mg Linearity ±0.2 mg
Tare Range Full Capacity Minimum Sample Weight (U=1% K=2) 16 mg
Minimum Sample Weight (as per USP) 160 mg Pan Size 90 Ø mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlite LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18ºC to 30ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 228.5 Weight approx. 9.3 kg