Aczet High Precision Balances are versatile and accurate, making them ideal for various weighing procedures. They are commonly used in educational laboratories, quality control, manufacturing, research, and fieldwork. With wide capacity options and excellent readability, they meet precision requirements in diverse settings.

Reliable and precise results

The sensor truly stands out with its unparalleled design based on electromagnetic force compensation (EMFC). Its exceptional performance meets the highest international standards. I am truly impressed by its unique features and the results it delivers.
Internal Calibration Professional Level CY-C Series
Motorized built-in weight internal calibration ensures precise weighing performance in any condition.
Environmental influence Professional Level CY-C Series
The Perfect Self Automatic Calibration (PSAC) function maintains accuracy by automatically calibrating the system based on time or temperature changes      
Standard Level CY Series External calibration
is the process of manually calibrating a balance with a predetermined mass.                                                             
 

Revolution in Mass Measurement Quantity

Our High Precision balance sets a new benchmark for mass measurement quality with the best-weighing accuracy and sd ≤ 1d repeatability. We adhere to strict USP requirements (chapters 41 and 1251) to ensure the highest level of quality in our measurements.
Overload Protection
Monitor the built-in capacity tracker to prevent overloading the weighing cell.

Strong and Sturdy Construction

• The solid construction and high-quality materials
• Solid Performance
• A protective cover is supplied as standard to safeguard

Efficient Functioning

A large grade 304 stainless steel pan with non-magnetic features is definitely a great addition to ensure better weighing performance. It's good to know that the balance is equipped with a weighing pan of size 190 x 205 mm.
Protection Class
The balance is IP 54 protection qualified that protects from dust and splashes of water.

10 Easy-to-use Built-in-Applications

• including density determination, check weighing, totaling, and formulation, simplify your routine weighing tasks.

Excellent Readable Display

• Bright LED backlit LCD display and large numbers
• LCD glass with higher contrast and wider viewing angle.
• Intuitive interface

Efficient Communication

• Standard USB and RS232 interface
• Windows direct communication to MS Excel or any other Windows applications

GLP Documentation

• Built-in real-time clock make sure that the data are a true reflection of the test results & is the traceable document in compliance with SOPS and GLP regulation

Easy Leveling

• Easy to view Round Circular Bubble Level
•  Large adjustable feet
• Levelling your balance is quick and easy.

Effortless Cleaning

• Washable parts dismantle in seconds
• No tools needed
• All parts dishwasher-safe
• Balance housing is smooth and easy to clean

Application Industries

•  Pharmaceutical, Cosmeceuticals, and Biotechnology Products Testing Laboratories
•  Chemical and Material Testing laboratories
•  Food and Beverages Testing Laboratories
•  Petroleum Product Testing Laboratories
•  Research  & NABL Laboratories and Academic Institutes

Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 3101C 3100 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 3101C Maximum Capacity 3100 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -3100 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Operating Temperature gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Units 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 4101C 4100 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 4101C Maximum Capacity 4100 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -4100 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 6101C 6100 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 6101C Maximum Capacity 6100 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range 6100 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 8101C 8100 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 8101C Maximum Capacity 8100 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -8100 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 10001C 10000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 10001C Maximum Capacity 10000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -10000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 12001C 12000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 12001C Maximum Capacity 12000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -12000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 3101 3100 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 3101 Maximum Capacity 3100 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -3100 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 4101 4100 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 4101 Maximum Capacity 4100 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -4100 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 6101 6100 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 6101 Maximum Capacity 6100 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -6100 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 8101 8100 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 8101 Maximum Capacity 8100 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -8100 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 10001 10000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 10001 Maximum Capacity 10000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -10000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 12001 12000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 12001 Maximum Capacity 12000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -12000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (2 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 7.3 kg