Our industrial high-capacity precision balances are the perfect solution, offering various capacities and readabilities to meet your needs. With a wide range of capacities from 15 kg to 50 kg and a readability of 0.1g and 1g, these balances provide accurate measurements for any job. Invest in our balances for efficient precision operations.

Reliable and precise results

New Weighing Sensor MonoTech Single block uniform structure ensures stable temperature characteristics, Excellent response time, and reliable corner-load performance ensuring reliability and long operational life. Its exceptional performance meets the highest international standards. I am truly impressed by its unique features and the results it delivers.
Internal Calibration Professional Level CY- HC Series
Motorized built-in weight internal calibration ensures precise weighing performance in any condition.
Environmental influence Professional Level CY- HC Series
The Perfect Self Automatic Calibration (PSAC) function maintains accuracy by automatically calibrating the system based on time or temperature changes.
Standard Level CY- H Series External calibration is the process of manually calibrating a balance with a predetermined mass.                        

Revolution in Mass Measurement Quantity

Our Industrial Precision Balance sets a new benchmark for mass measurement quality with the best weighing accuracy and sd ≤ 1d repeatability. We adhere to strict USP requirements (chapters 41 and 1251) to ensure the highest level of quality in our measurements. 
Overload Protection    
An in-built 4-point protection system prevents balance overloading, this ensures safety in case too heavy a  load is applied onto the weighing pan.
                                                                                                                                           
 

Strong and Sturdy Construction

• The solid construction and high-quality materials
• Solid Performance
• A protective cover is supplied as standard to safeguard

Efficient Functioning

A large grade 304 stainless steel pan with non-magnetic features is definitely a great addition to ensure better weighing performance. It's good to know that the balance is equipped with a weighing pan of size 370 x 270 mm.
Protection Class
The balance is IP 54 protection qualified which protects from dust and splashes of water.

10 Easy-to-use Built-in-Applications

• including density determination, check weighing, totaling, and formulation, simplify your routine weighing tasks.

Easy-to-Read LCD Screen

• Bright LED backlit LCD display and large numbers
• LCD glass with higher contrast and wider viewing angle.
• Intuitive interface
 

Quick and Error Free Documentation

• Standard RS232 interface
• Windows direct communication to MS Excel or any other Windows applications

GLP Documentation

• Built-in real-time clock make sure that the data are a true reflection of the test results & is the traceable document in compliance with SOPS and GLP regulation.
 

Easy Leveling

• Easy to view Round Circular Bubble Level
•  Large adjustable feet
• Levelling your balance is quick and easy.

Effortless Cleaning

• Washable parts dismantle in seconds
• No tools needed
• All parts dishwasher-safe
• Balance housing is smooth and easy to clean

Application Industries

•  Pharmaceutical, Cosmeceuticals, and Biotechnology Products Testing Laboratories
•  Chemical and Material Testing laboratories
•  Food and Beverages Testing Laboratories
•  Petroleum Product Testing Laboratories
•  Research  & NABL Laboratories and Academic Institutes

Professional Level CY-HC Series Model Maximum Capacity Minimum load Readability Repeatability
CY 15001 HC 15000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 15001 HC Maximum Capacity 15000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -15000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 370 x 270 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg
Professional Level CY-HC Series Model Maximum Capacity Minimum load Readability Repeatability
CY 20001 HC 20000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 20001 HC Maximum Capacity 20000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -20000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 370 x 270 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg
Professional Level CY-HC Series Model Maximum Capacity Minimum load Readability Repeatability
CY 25001 HC 25000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 25001 HC Maximum Capacity 25000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -25000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 370 x 270 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg
Professional Level CY-HC Series Model Maximum Capacity Minimum load Readability Repeatability
CY 35001 HC 35000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 35001 HC Maximum Capacity 35000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -35000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 370 x 270 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg
Professional Level CY-HC Series Model Maximum Capacity Minimum load Readability Repeatability
CY 50000 HC 50000 gm 1 gm ±1 gm
Get A Quote
Full Specs
Model CY 50000 HC Maximum Capacity 50000 gm
Minimum load Readability 1 gm
Repeatability ±1 gm Linearity ±2 gm
Tare Range -50000 gm Minimum Sample Weight (U=1% K=2) 82 gm
Minimum Sample Weight (as per USP) 820 gm Pan Size 370 x 270 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg
Standard Level CY-H Series Model Maximum Capacity Minimum load Readability Repeatability
CY 15001 H 15000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 15001 H Maximum Capacity 15000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -15000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 370 x 270 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg
Standard Level CY-H Series Model Maximum Capacity Minimum load Readability Repeatability
CY 20001 H 20000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 20001 H Maximum Capacity 20000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -20000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 370 x 270 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg
Standard Level CY-H Series Model Maximum Capacity Minimum load Readability Repeatability
CY 25001 H 25000 gm 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 25001 H Maximum Capacity 25000 gm
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range -25000 gm Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 370 x 270
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg
Standard Level CY-H Series Model Maximum Capacity Minimum load Readability Repeatability
CY 35001 H 35 kg 5 gm 0.1 gm ±0.1 gm
Get A Quote
Full Specs
Model CY 35001 H Maximum Capacity 35 kg
Minimum load 5 gm Readability 0.1 gm
Repeatability ±0.1 gm Linearity ±0.2 gm
Tare Range Full Capacity Minimum Sample Weight (U=1% K=2) 8.2 gm
Minimum Sample Weight (as per USP) 82 gm Pan Size 370 x 270 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg
Standard Level CY-H Series Model Maximum Capacity Minimum load Readability Repeatability
CY 50000 H 50000 gm - 1 gm ±1 gm
Get A Quote
Full Specs
Model CY 50000 H Maximum Capacity 50000 gm
Minimum load - Readability 1 gm
Repeatability ±1 gm Linearity ±2 gm
Tare Range -50000 gm Minimum Sample Weight (U=1% K=2) 82 gm
Minimum Sample Weight (as per USP) 820 gm Pan Size 370 x 270 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2ppm (2 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 517 x 302 x 130 Weight approx. 16.3 kg