• Pharmaceutical, Cosmeceuticals, and Biotechnology Products Testing Laboratories
• Chemical and Material Testing laboratories
• Food and Beverages Testing Laboratories
• Petroleum Product Testing Laboratories
• Research & NABL Laboratories and Academic Institutes
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 123C | 120 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 123C | Maximum Capacity | 120 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ± 0.002 gm |
Tare Range | - 120 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 223C | 220 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 223C | Maximum Capacity | 220 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | -220 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 323C | 320 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 323C | Maximum Capacity | 320 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 320 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 363C | 360 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 363C | Maximum Capacity | 360 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 360 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 423C | 420 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 423C | Maximum Capacity | 420 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 420 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 513C | 510 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 513C | Maximum Capacity | 510 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 510 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 623C | 620 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 623C | Maximum Capacity | 620 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | -620 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 723C | 720 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 723C | Maximum Capacity | 720 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 720 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 1003C | 1000 gm | 0.02 gm | 0.001 gm | ±0.002 gm | |
Get A Quote
Full Specs
|
Model | CY 1003C | Maximum Capacity | 1000 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.002 gm | Linearity | ±0.005 gm |
Tare Range | - 1000 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 2003C | 2000 gm | 0.02 gm | 0.001 gm | ±0.003 gm | |
Get A Quote
Full Specs
|
Model | CY 2003C | Maximum Capacity | 2000 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.003 gm | Linearity | ±0.005 gm |
Tare Range | - 2000 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Professional Level CY-C Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 3003C | 3000 gm | 0.02 gm | 0.001 gm | ±0.003 gm | |
Get A Quote
Full Specs
|
Model | CY 3003C | Maximum Capacity | 3000 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.003 gm | Linearity | ±0.005 gm |
Tare Range | - 3000 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | Motorised Internal Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15° to 35°C | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 123 | 120 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 123 | Maximum Capacity | 120 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 120 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / ºC) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 223 | 220 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 223 | Maximum Capacity | 220 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 220 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 323 | 320 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 323 | Maximum Capacity | 320 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 320 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 363 | 360 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 363 | Maximum Capacity | 360 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 360 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 423 | 420 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 423 | Maximum Capacity | 420 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 420 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 513 | 510 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 513 | Maximum Capacity | 510 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | -510 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 623 | 620 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 623 | Maximum Capacity | 620 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 620 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 723 | 720 gm | 0.02 gm | 0.001 gm | ±0.001 gm | |
Get A Quote
Full Specs
|
Model | CY 723 | Maximum Capacity | 720 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.001 gm | Linearity | ±0.002 gm |
Tare Range | - 720 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 1003 | 1000 gm | 0.02 gm | 0.001 gm | ±0.002 gm | |
Get A Quote
Full Specs
|
Model | CY 1003 | Maximum Capacity | 1000 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.002 gm | Linearity | ±0.005 gm |
Tare Range | - 1000 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 2003 | 2000 gm | 0.02 gm | 0.001 gm | ±0.003 gm | |
Get A Quote
Full Specs
|
Model | CY 2003 | Maximum Capacity | 2000 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.003 gm | Linearity | ±0.005 gm |
Tare Range | - 2000 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Compliance | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Power Supply | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Standard Level CY Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 3003 | 3000 gm | 0.02 gm | 0.001 gm | ±0.003 gm | |
Get A Quote
Full Specs
|
Model | CY 3003 | Maximum Capacity | 3000 gm |
Minimum load | 0.02 gm | Readability | 0.001 gm |
Repeatability | ±0.003 gm | Linearity | ±0.005 gm |
Tare Range | - 3000 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 x 128 mm |
Response Time | 2 - 3 Sec. | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / °C) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 7.5 kg |
Dual Range CY 2202 DR Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 2202 DR | 200 / 2000 gm | 0.02 gm | 0.001 / 0.01 gm | 0.001 / 0.01 gm | |
Get A Quote
Full Specs
|
Model | CY 2202 DR | Maximum Capacity | 200 / 2000 gm |
Minimum load | 0.02 gm | Readability | 0.001 / 0.01 gm |
Repeatability | 0.001 / 0.01 gm | Linearity | 0.002 / 0.02 gm |
Tare Range | -2000 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 sec | Display | Alpha Numeric Backlit LCD Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / ºC) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 6.8 kg |
Dual Range CY 3102 DR Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 3102 DR | 300 / 3000 gm | 0.02 gm | 0.001 / 0.01 gm | ±0.001 / 0.01 gm | |
Get A Quote
Full Specs
|
Model | CY 3102 DR | Maximum Capacity | 300 / 3000 gm |
Minimum load | 0.02 gm | Readability | 0.001 / 0.01 gm |
Repeatability | ±0.001 / 0.01 gm | Linearity | ±0.002 / 0.02 gm |
Minimum Sample Weight (U=1% K=2) | 0.1 gm | Minimum Sample Weight (as per USP) | 1 gm |
Tare Range | -3000 gm | Pan Size | 128 X 128 mm |
Display | Alpha Numeric Backlit LCD Display | Response Time | 2 - 3 sec |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / ºC) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 6.8 kg |
Dual Range CY 4102 DR Series | Model | Maximum Capacity | Minimum load | Readability | Repeatability |
CY 4102 DR | 400 / 4000 gm | 100 mg | 0.001 / 0.01 gm | 0.001 / 0.01 gm | |
Get A Quote
Full Specs
|
Model | CY 4102 DR | Maximum Capacity | 400 / 4000 gm |
Minimum load | 100 mg | Readability | 0.001 / 0.01 gm |
Repeatability | 0.001 / 0.01 gm | Linearity | 0.002 / 0.02 gm |
Tare Range | -4000 gm | Minimum Sample Weight (U=1% K=2) | 0.1 gm |
Minimum Sample Weight (as per USP) | 1 gm | Pan Size | 128 X 128 mm |
Response Time | 2 - 3 sec | Display | Alpha Numeric LCD Backlit Display |
Calibration | External Calibration | Units | gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS |
Operating Temperature | 15º to 35ºC | Sensitivity Drift | ± 2 ppm (1 x 10⁻⁶ / ºC) |
Interface | RS 232C Optional USB (Windows direct communication). | Application Modes | PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc. |
Power Supply | DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz | Compliance | ISO, GLP / GMP & USP |
Balance Size (WxDxH) mm | 342.5 x 212 x 271 / Chamber Height 169.5 | Weight approx. | 6.8 kg |