Precision Balances Accurate Measurements for Your Needs

Our Precision Balances are essential tools for accurate mass measurements in laboratories and other settings. They are meticulously engineered to provide highly precise readings, even for the smallest weight increments. With capacities ranging from 120 g to 3000 g and a readability of 0.001 gm, they cater to diverse weighing needs. Whether for small-scale research or larger industrial applications, our Precision Balances cover the entire spectrum of precision operations.

Reliable and precise results

The sensor truly stands out with its unparalleled design based on electromagnetic force compensation (EMFC). Its exceptional performance meets the highest international standards. I am truly impressed by its unique features and the results it delivers.
Internal Calibration Professional Level CY-C Series
Motorized built-in weight internal calibration ensures precise weighing performance in any condition.
Environmental influence Professional Level CY-C Series
The Perfect Self Automatic Calibration (PSAC) function maintains accuracy by automatically calibrating the system based on time or temperature changes 
Standard Level CY Series External calibration 
Is the process of manually calibrating a balance with a predetermined mass.                                                             
 

Revolution in Mass Measurement Quantity

Our Precision balance sets a new benchmark for mass measurement quality with the best -weighing accuracy and sd ≤ 1d repeatability. We adhere to strict USP requirements (chapters 41 and 1251) to ensure the highest level of quality in our measurements.
Overload Protection
Monitor the built-in capacity tracker to prevent overloading the weighing cell.
 

Strong and Sturdy Construction

• The solid construction and high-quality materials
• Solid Performance
• A protective cover is supplied as standard to safeguard

Efficient Functioning

The balance's glass draft shield with a three-side opening chamber is exceptionally spacious and user-friendly, providing ample space to work without the worry of spills.
On request provide The top-side open draft shield is designed to provide easy access to the weighing pan and sample
Protection Class
The balance is IP 54 protection qualified that protects from dust and splashes of water.

10 Easy-to-use Built-in-Applications

• including density determination, check weighing, totaling, and formulation, simplify your routine weighing tasks.

Excellent Readable Display

• Bright LED backlit LCD display and large numbers
• LCD glass with higher contrast and wider viewing angle.
• Intuitive interface

Quick and Error Free Documentation

• Standard USB and RS232 interface
• Windows direct communication to MS Excel or any other Windows applications

GLP Documentation

• Built-in real-time clock make sure that the data are a true reflection of the test results & is the traceable document in compliance with SOPS and GLP regulation.

Easy Leveling

• Easy to view Round Circular Bubble Level
•  Large adjustable feet
• Levelling your balance is quick and easy.

Effortless Cleaning

• The draft shields can be easily dismantled and assembled, making it  convenient to keep the balance clean and tidy.
 

Application Industries

• Pharmaceutical, Cosmeceuticals, and Biotechnology Products Testing Laboratories
• Chemical and Material Testing laboratories
• Food and Beverages Testing Laboratories
• Petroleum Product Testing Laboratories
• Research  & NABL Laboratories and Academic Institutes

 

 

Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 123C 120 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 123C Maximum Capacity 120 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ± 0.002 gm
Tare Range - 120 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 223C 220 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 223C Maximum Capacity 220 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range -220 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 323C 320 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 323C Maximum Capacity 320 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 320 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 363C 360 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 363C Maximum Capacity 360 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 360 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 423C 420 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 423C Maximum Capacity 420 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 420 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 513C 510 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 513C Maximum Capacity 510 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 510 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 623C 620 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 623C Maximum Capacity 620 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range -620 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 723C 720 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 723C Maximum Capacity 720 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 720 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 1003C 1000 gm 0.02 gm 0.001 gm ±0.002 gm
Get A Quote
Full Specs
Model CY 1003C Maximum Capacity 1000 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.002 gm Linearity ±0.005 gm
Tare Range - 1000 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 2003C 2000 gm 0.02 gm 0.001 gm ±0.003 gm
Get A Quote
Full Specs
Model CY 2003C Maximum Capacity 2000 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.003 gm Linearity ±0.005 gm
Tare Range - 2000 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 3003C 3000 gm 0.02 gm 0.001 gm ±0.003 gm
Get A Quote
Full Specs
Model CY 3003C Maximum Capacity 3000 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.003 gm Linearity ±0.005 gm
Tare Range - 3000 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15° to 35°C Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor, input 100 ~ 240 0.8A output 13V / 15 .A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 123 120 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 123 Maximum Capacity 120 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 120 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 223 220 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 223 Maximum Capacity 220 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 220 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 323 320 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 323 Maximum Capacity 320 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 320 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 363 360 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 363 Maximum Capacity 360 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 360 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 423 420 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 423 Maximum Capacity 420 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 420 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 513 510 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 513 Maximum Capacity 510 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range -510 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 623 620 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 623 Maximum Capacity 620 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 620 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 723 720 gm 0.02 gm 0.001 gm ±0.001 gm
Get A Quote
Full Specs
Model CY 723 Maximum Capacity 720 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.001 gm Linearity ±0.002 gm
Tare Range - 720 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 1003 1000 gm 0.02 gm 0.001 gm ±0.002 gm
Get A Quote
Full Specs
Model CY 1003 Maximum Capacity 1000 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.002 gm Linearity ±0.005 gm
Tare Range - 1000 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 2003 2000 gm 0.02 gm 0.001 gm ±0.003 gm
Get A Quote
Full Specs
Model CY 2003 Maximum Capacity 2000 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.003 gm Linearity ±0.005 gm
Tare Range - 2000 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Compliance DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Power Supply ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 3003 3000 gm 0.02 gm 0.001 gm ±0.003 gm
Get A Quote
Full Specs
Model CY 3003 Maximum Capacity 3000 gm
Minimum load 0.02 gm Readability 0.001 gm
Repeatability ±0.003 gm Linearity ±0.005 gm
Tare Range - 3000 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 7.5 kg
Dual Range CY 2202 DR Series Model Maximum Capacity Minimum load Readability Repeatability
CY 2202 DR 200 / 2000 gm 0.02 gm 0.001 / 0.01 gm 0.001 / 0.01 gm
Get A Quote
Full Specs
Model CY 2202 DR Maximum Capacity 200 / 2000 gm
Minimum load 0.02 gm Readability 0.001 / 0.01 gm
Repeatability 0.001 / 0.01 gm Linearity 0.002 / 0.02 gm
Tare Range -2000 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 sec Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 6.8 kg
Dual Range CY 3102 DR Series Model Maximum Capacity Minimum load Readability Repeatability
CY 3102 DR 300 / 3000 gm 0.02 gm 0.001 / 0.01 gm ±0.001 / 0.01 gm
Get A Quote
Full Specs
Model CY 3102 DR Maximum Capacity 300 / 3000 gm
Minimum load 0.02 gm Readability 0.001 / 0.01 gm
Repeatability ±0.001 / 0.01 gm Linearity ±0.002 / 0.02 gm
Minimum Sample Weight (U=1% K=2) 0.1 gm Minimum Sample Weight (as per USP) 1 gm
Tare Range -3000 gm Pan Size 128 X 128 mm
Display Alpha Numeric Backlit LCD Display Response Time 2 - 3 sec
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 6.8 kg
Dual Range CY 4102 DR Series Model Maximum Capacity Minimum load Readability Repeatability
CY 4102 DR 400 / 4000 gm 100 mg 0.001 / 0.01 gm 0.001 / 0.01 gm
Get A Quote
Full Specs
Model CY 4102 DR Maximum Capacity 400 / 4000 gm
Minimum load 100 mg Readability 0.001 / 0.01 gm
Repeatability 0.001 / 0.01 gm Linearity 0.002 / 0.02 gm
Tare Range -4000 gm Minimum Sample Weight (U=1% K=2) 0.1 gm
Minimum Sample Weight (as per USP) 1 gm Pan Size 128 X 128 mm
Response Time 2 - 3 sec Display Alpha Numeric LCD Backlit Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 271 / Chamber Height 169.5 Weight approx. 6.8 kg