Aczet is a great option to consider for routine weighing procedures. Its generous pan size and weight range make it perfect for a variety of tasks in educational laboratories, quality control, manufacturing, research, and fieldwork.
Top loading balances came in such a wide range of capacities and precision requirements! It's really impressive that they can cover all of the needs of a laboratory, from 310 g up to 6100 g with readability down to 0.01 g be an excellent choice for labs with varied needs

Reliable and precise results

The sensor truly stands out with its unparalleled design based on electromagnetic force compensation (EMFC). Its exceptional performance meets the highest international standards. I am truly impressed by its unique features and the results it delivers.
Internal Calibration Professional Level CY-C Series
Motorized built-in weight internal calibration ensures precise weighing performance in any condition.
Environmental influence Professional Level CY-C Series
The Perfect Self Automatic Calibration (PSAC) function maintains accuracy by automatically calibrating the system based on time or temperature changes
Standard Level CY Series External calibration
 Is the process of manually calibrating a balance with a predetermined mass.             

Revolution in Mass Measurement Quantity

Our Top Pan balance sets a new benchmark for mass measurement quality with the best weighing accuracy and sd ≤ 1d repeatability. We adhere to strict USP requirements (chapters 41 and 1251) to ensure the highest level of quality in our measurements.
Overload Protection
Monitor the built-in capacity tracker to prevent overloading the weighing cell.

Strong and Sturdy Construction

• The solid construction and high-quality materials
• Solid Performance
• A protective cover is supplied as standard to safeguard

Efficient Functioning

Top loading balances 310 g up to 610 g balance pan size of 128 x 128 mm is perfect for any laboratory, and the glass draft shield chamber is a great design choice. I also appreciate the doors' ability to slide open widely, which can prevent accidental spillage and make it easier to place large glassware on the pan.
The 1202 g to 6100 g balance does not have a draft shield. The weighing pan is open meaning that items can directly be added to the scale.
Protection Class
The balance is IP 54 protection qualified that protects from dust and splashes of water.

10 Easy-to-use Built-in-Applications

• Including density determination, check weighing, totaling, and formulation, simplify your routine weighing tasks.

 

Excellent Readable Display

• Bright LED backlit LCD display and large numbers
• LCD glass with higher contrast and wider viewing angle.
• Intuitive interface

Efficient Communication

• Standard USB and RS232 interface
• Windows direct communication to MS Excel or any other Windows applications

GLP Documentation

• Built-in real-time clock make sure that the data are a true reflection of the test results & is the traceable document in compliance with SOPS and GLP regulation

Easy Leveling

• Easy to view Round Circular Bubble Level
•  Large adjustable feet
• Levelling your balance is quick and easy.

Effortless Cleaning

• Washable parts dismantle in seconds
• No tools needed
• All parts dishwasher-safe
• Balance housing is smooth and easy to clean

Application Industries

• Pharmaceutical, Cosmeceuticals, and Biotechnology  Products Testing Laboratories
• Chemical and Material Testing laboratories
• Food and Beverages Testing Laboratories
• Petroleum Product Testing Laboratories
• Research  & NABL Laboratories and Academic Institutes

Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 312 C 310 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 312 C Maximum Capacity 310 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -310 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 158.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 612 C 610 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 612 C Maximum Capacity 610 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range - 610 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 158.5 Weight approx. 7.5 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 1202 C 1200 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 1202 C Maximum Capacity 1200 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range - 1200 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 2202 C 2200 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 2202 C Maximum Capacity 2200 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -2200 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 3102 C 3100 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 3102 C Maximum Capacity 3100 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -3100 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 4102 C 4100 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 4102 C Maximum Capacity 4100 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -4100 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg
Professional Level CY-C Series Model Maximum Capacity Minimum load Readability Repeatability
CY 6102 C 6100 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 6102 C Maximum Capacity 6100 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.03 gm
Tare Range -6100 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 198 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 312 310 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 312 Maximum Capacity 310 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -310 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 158.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 612 610 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 612 Maximum Capacity 610 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -610 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 128 x 128 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 341 / Chamber Height 158.5 Weight approx. 7.5 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 1202 1200 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 1202 Maximum Capacity 1200 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -1200 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 2202 2200 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 2202 Maximum Capacity 2200 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -2200 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg
"Hot" Warning
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 3102 3100 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 3102 Maximum Capacity 3100 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -3100 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 4102 4100 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 4102 Maximum Capacity 4100 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.02 gm
Tare Range -4100 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg
Standard Level CY Series Model Maximum Capacity Minimum load Readability Repeatability
CY 6102 6100 gm 0.5 gm 0.01 gm ±0.01 gm
Get A Quote
Full Specs
Model CY 6102 Maximum Capacity 6100 gm
Minimum load 0.5 gm Readability 0.01 gm
Repeatability ±0.01 gm Linearity ±0.03 gm
Tare Range -6100 gm Minimum Sample Weight (U=1% K=2) 1 gm
Minimum Sample Weight (as per USP) 10 gm Pan Size 190 x 205 mm
Response Time 2 - 3 Sec. Display Alpha Numeric Backlit LCD Display
Calibration External Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 15º to 35ºC Sensitivity Drift ± 2 ppm (1 x 10⁻⁶ / °C)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adaptor,input 100 ~ 240 0.8A output 13V / 15.A, 50-60Hz Compliance ISO, GLP / GMP & USP
Balance Size (WxDxH) mm 342.5 x 212 x 89.5 Weight approx. 6.8 kg