Microbalance is the first choice for measuring the smallest sample quantity. Excellent performance in challenging conditions, the best operating temperature range, and resistance to external conditions minimize the environmental influence on the operation of the balance. A weighing instrument with a wide range of capacities from 2 g up to 21 g and a readability of 1 µg (microgram) offers exceptional precision and versatility for weighing applications that require highly accurate measurements.
Excellent Weighing Performance
The Microbalance, with its two-terminal concept, offers excellent weighing performance by separating the electronics from the precise mechanical measuring cell. This design helps eliminate the effects of temperature and its influence on the balance's performance.

The Brilliant Proven Technology

The technology sensor truly stands out with its unparalleled design based on electromagnetic force compensation (EMFC). Its exceptional performance meets the highest international standards. I am truly impressed by its unique features and the results it delivers.
Internal Calibration
Motorized built-in weight internal calibration ensures precise weighing performance in any condition.
Environmental influence 
The Perfect Self Automatic Calibration (PSAC) function maintains accuracy by automatically calibrating the system based on time or temperature changes.

Revolution in Mass Measurement Quantity

Our weighing system sets a new benchmark for mass measurement quality with the best weighing accuracy and sd ≤ 1d repeatability. We adhere to strict USP requirements (chapters 41 and 1251) to ensure the highest level of quality in our measurements.
Overload Protection
Monitor the built-in capacity tracker to prevent overloading the weighing cell.

Strong and Sturdy Construction

• The solid construction and high-quality materials
• Solid Performance
• A protective cover is supplied as standard to safeguard
 

Easy-to-Read LCD Screen

• Bright LED backlit LCD display and large numbers
• LCD glass with higher contrast and wider viewing angle.
• Intuitive interface
 

10 Easy-to-use Built-in-Applications

• including density determination, check weighing, totaling, and formulation, simplify your routine weighing tasks.

Easy Leveling

• Easy to view Round Circular Bubble Level
•  Large adjustable feet
• Levelling your balance is quick and easy.

Efficient Communication

• Standard USB and RS232 interface
• Windows direct communication to MS Excel or any other Windows applications
 

 

GLP Documentation

• Built-in real-time clock make sure that the data are a true reflection of the test results & is the traceable document in compliance with SOPS and GLP regulation.

Easy cleaning

• The draft shields can be easily dismantled and assembled, making it really convenient to keep the balance clean and tidy.

Optional AntiStatic Ionizer

• To help to address one of the major enemy of micro-weighing, the freestanding optional CI - 01 ionizer removes electrostatic charges on samples and containers help accurate weighing results.

CM Series Model Maximum Capacity Minimum load Readability Repeatability
CM 5 5 gm 100 μg 1 μg ±1 μg
Get A Quote
Full Specs
Model CM 5 Maximum Capacity 5 gm
Minimum load 100 μg Readability 1 μg
Repeatability ±1 μg Linearity ±6 μg
Tare Range -5 gm Minimum Sample Weight (U=1% K=2) 0.24 mg
Minimum Sample Weight (as per USP) 2.4 mg Pan Size 30 mm Ø
Response Time 8 - 10 sec Display Alpha Numeric LCD Backlit Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18°C to 30 °C Sensitivity Drift ± 1ppm (1 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adapter, input 100 ~ 240 0.8A output 13V / 1.5A Compliance ISO / GLP / GMP Compliance
Balance Size (WxDxH) mm Mechanical Box : 360 (L) x 140 (W) x 146 (H) Electronic Box : 240 (W) x 210 (D) x 65 (H) Weight approx. 12 kg /14 kg
CM Series Model Maximum Capacity Minimum load Readability Repeatability
CM 6 6.1 gm 100 μg 1 μg ±1 μg
Get A Quote
Full Specs
Model CM 6 Maximum Capacity 6.1 gm
Minimum load 100 μg Readability 1 μg
Repeatability ±1 μg Linearity ±6 μg
Tare Range - 6.1 gm Minimum Sample Weight (U=1% K=2) 0.24 mg
Minimum Sample Weight (as per USP) 2.4 mg Pan Size 30 mm Ø
Response Time 8 - 10 sec Display Alpha Numeric LCD Backlit Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18°C to 30 °C Sensitivity Drift ± 1ppm (1 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adapter, input 100 ~ 240 0.8A output 13V / 1.5A Compliance ISO / GLP / GMP Compliance
Balance Size (WxDxH) mm Mechanical Box : 360 (L) x 140 (W) x 146 (H) Electronic Box : 240 (W) x 210 (D) x 65 (H) Weight approx. 12 kg / 14.kg
CM Series Model Maximum Capacity Minimum load Readability Repeatability
CM 11 11 gm 100 μg 1 μg ±1.2 μg
Get A Quote
Full Specs
Model CM 11 Maximum Capacity 11 gm
Minimum load 100 μg Readability 1 μg
Repeatability ±1.2 μg Linearity ±6 μg
Tare Range -11 gm Minimum Sample Weight (U=1% K=2) 0.24 mg
Minimum Sample Weight (as per USP) 2.4 mg Pan Size 30 mm Ø
Response Time 8 - 10 sec Display Alpha Numeric LCD Backlit Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18°C to 30°C Sensitivity Drift ± 1ppm (1 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adapter, input 100 ~ 240 0.8A output 13V / 1.5A Compliance ISO / GLP / GMP Compliance
Balance Size (WxDxH) mm Mechanical Box : 360 (L) x 140 (W) x 146 (H) Electronic Box : 240 (W) x 210 (D) x 65 (H) Net Weight / Gross Weight 12 kg / 14.kg
Laser Source Laser Power
Beam Quality M2 Pulse Repetition Rate
Marking Area (mm) Marking Speed
Laser Frequency Cooling System
Minimum Width Minimum Character
Laser wavelength Maximum Average Power
Max pulse energy Depth
Pulse width Frequency (Khz)
Spot Size Power
Installation Space Environment
Temperature Maximum Laser Power
Peak Pulse-Power Avg. Pulse-Power
Frequency of Repetition Microscope
Program Program Memory
Product Flow Rate (RO.UP) Daily Volume
Water Quality Display Range
Controller Functions Safety Function
Optional Function FAT
FAT- Accuracy SNF
SNF- Accuracy Density
Density- Accuracy Protein
Protein- Accuracy Lactose
Lactose- Accuracy Salts
Salts- Accuracy Added Water
Added Water- Accuracy Freezing Point
Freezing Point- Accuracy Sample Temperature
Sample Temperature- Accuracy Sample Volume
Measurement Speed Humidity
Material Working Bed (L x W)
Max. Sample weight Test
Housing Dimension (mm) Min. Character Size
Size per Dot Marking Depth
Rotary Mark Marking Type
Inside Ring Size Marking Outside Ring Size Marking
Pendant Sculpture Range Ring Width
Font Software
Marking & Cutting Depth Dust Collector
Repeatability Tare Range Subtractive
Accuracy Measure Density (g/cm^3)
Minimum Sample Weight Weight In Air Pan Size (mm)
Weight In Water Pan Size (mm) Access Control
Cooling Type Pedestal
Eccentricity Deviation (Test Load) Housing
Temperature- Offset Calibration Temperature- Calibration Range
mV- Measurement Modes
CM Series Model Maximum Capacity Minimum load Readability Repeatability
CM 21 21 gm 100 μg 1 μg ±1.5 μg
Get A Quote
Full Specs
Model CM 21 Maximum Capacity 21 gm
Minimum load 100 μg Readability 1 μg
Repeatability ±1.5 μg Linearity ±7 μg
Tare Range - 21 gm Minimum Sample Weight (U=1% K=2) 0.24 mg
Minimum Sample Weight (as per USP) 2.4 mg Pan Size 30 mm Ø
Response Time 8 - 10 sec Display Alpha Numeric LCD Backlit Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18°C to 30 °C Sensitivity Drift ± 1ppm (1 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adapter, input 100 ~ 240 0.8A output 13V / 1.5A Compliance ISO / GLP / GMP Compliance
Balance Size (WxDxH) mm Mechanical Box : 360 (L) x 140 (W) x 146 (H) Electronic Box : 240 (W) x 210 (D) x 65 (H) Weight approx. 12 kg / 14 kg
CM Series Model Maximum Capacity Minimum load Readability Repeatability
CM 31 31 gm 100 μg 1 μg ±2 μg
Get A Quote
Full Specs
Model CM 31 Maximum Capacity 31 gm
Minimum load 100 μg Readability 1 μg
Repeatability ±2 μg Linearity ±8 μg
Tare Range - 31 gm Minimum Sample Weight (U=1% K=2) 0.4 mg
Minimum Sample Weight (as per USP) 4 mg Pan Size 30 mm Ø
Response Time 8 - 10 sec Display Alpha Numeric LCD Backlit Display
Calibration Motorised Internal Calibration Units gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
Operating Temperature 18°C to 30 °C Sensitivity Drift ± 1ppm (1 x 10⁻⁶ / ºC)
Interface RS 232C Optional USB (Windows direct communication). Application Modes PCS, % Weighing, Animal / Dynamic Weighing, Check Weighing, Automatic Density Determination, Formulation Automatic Statistic Calculator etc.
Power Supply DC Adapter, input 100 ~ 240 0.8A output 13V / 1.5A Compliance ISO / GLP / GMP Compliance
Balance Size (WxDxH) mm Mechanical Box : 360 (L) x 140 (W) x 146 (H) Electronic Box : 240 (W) x 210 (D) x 65 (H) Weight approx. 12 kg / 14 kg